MPPT 99% Solar Water Pump Inverter Single Phase Three Phase 0.75KW - 710KW
Place of Origin China
Brand Name VEIKONG
Certification CE
Model Number VFD500-PV
Minimum Order Quantity 1
Price Negotiable
Packaging Details the power less than 45kw use Carton, starting from 45kw use Wooden case
Delivery Time 3 days, depend on the order quantity
Payment Terms L/C, T/T, Western Union
Supply Ability 15000pcs per Month
Product Details
Product Name Single Phase Inverter 0.75kw-710kw Voltage 220v
Application Submersible Pump Protect Level Ip20 , Ip65
Display LCD, LED Dual Display Screen OEM YES
High Light

MPPT Solar water pump inverter

,

Solar water pump inverter 0.75KW

,

Single Phase Solar water pump inverter

Product Description

MPPT 99% Solar water pump inverter single phase three phase 0.75KW-710KW

 

VEIKONG is professional manufacturer of solar pump inverter, variable frequency dirve, soft starter.

 

 

Electrical Specifications and Power degree

 

  220V 380V
Max input DC voltage 450V 810V
DC voltage range 150~450VDC 300~810VDC
Normal working DC voltage 260V-400V 400V-650V
Recommended input mppt voltage 330V 550V
MPPT efficiency >99%
Rated output voltage 1/3-phase 220VAC 3-phase 380-480VAC
Output frequency range 50/60Hz
Max efficiency of the machine 99%
Power range 220v 0.75kw to 75kw, 380v 1.5kw-160kw
Cooling method Air cooling
Protection degree IP20/IP65
Altitude Below 1000m; above 1% for every additional 100m.
Standard CE/ROHS

 

Noted: We suggest solar panel power should be 1.3-1.4 times higher than solar pump power ,

And solar pump inverter power should be higher level than solar pump.

When solar pump distance to inverter higher than 100m,

It should be equipped with Output reactor or higher level power inverter.

For Solar panel,total VOC less than Maximum DC voltage of inverter and Solar panel vmp is recommend

530V for 380V pump and 305V for 220V pump.

 

 

VEIKONG VFD500-PV solar pump inverter Features:

 

●  Worldwide applicable voltage levels and power ranges

Supports 220V single/three-phase, 380V three-phase water pumps, power ranges from 0.75kW to 710kW.

 

●  Fully intelligent

  • Simply connect the photovoltaic panels to the inverter, no need to set any parameters and the water pump will start automatically when powered on.

  • Automatic adjustment of the water output in response to changes in sunlight.

  • Automatic dormancy in weak light (e.g. after sunset), withdrawal from dormancy in strong light (e.g. at sunrise).

  • Automatic dormancy when the water level is high and automatic restart when the water level is low, enabling automatic water level control.

  • Specially designed for water pump users, easy to operate and adaptable to various applications.

 

●  Multiple protection

Protection features such as PV over-voltage protection, PV reverse polarity alarm, automatic over-temperature derating, etc. can effectively extend the product life

 

●  Advanced MPPT technology

Ensures solar tracking efficiency up to 99%

 

●  AC/DC switching solution

The whole series of products can automatically switch between PV DC input and grid AC input, which can meet 24-hour water consumption and no manual operation is required.

 

Mode Range

 

Drive model Max DC input current (A) Rated output current (A) Applicable water pump (kW)
VFD500M-40T00150-PV 6.1 3.7 1.5
VFD500M-40T00220-PV 7.1 5 2.2
VFD500M-40T00400-PV 16.5 9.4 4
VFD500M-40T00550-PV 23.9 13 5.5
VFD500M-40T00750-PV 30.6 17 7.5
VFD500-40T00150-PV 6.1 3.7 1.5
VFD500-40T00220-PV 7.1 5 2.2
VFD500-40T00400-PV 16.5 9.4 4
VFD500-40T00550-PV 23.9 13 5.5
VFD500-40T00750-PV 30.6 17 7.5
VFD50040T01100-PV 39.2 25 11
VFD500-40T01500-PV 49.0 32 15
VFD500-40T01850-PV 57 37 18.5
VFD500-40T02200-PV 69 45 22
VFD500-40T03000-PV 91 60 30
VFD500-40T03700-PV 114 75 37
VFD500-40T04500-PV 146 90 45
VFD500-40T05500-PV 190 112 55
VFD500-40T07500-PV 237 152 75
VFD500-40T09000-PV 273 176 90
VFD500-40T11000-PV 319 210 110
VFD500-40T13200-PV 389 253 132
220V single phase or three phase level
VFD500-20T00075-PV 6.7 4.5 0.75
VFD500-20T00150-PV 9.9 7 1.5
VFD500-20T00220-PV 14.1 10.6 2.2
VFD500-20T00400-PV 22.6 17 4
VFD500M-20T00150-PV 9.9 7 1.5
VFD500M-20T00220-PV 14.1 10.6 2.2

 

Product Application
MPPT 99% Solar Water Pump Inverter Single Phase Three Phase 0.75KW - 710KW
 
MPPT 99% Solar Water Pump Inverter Single Phase Three Phase 0.75KW - 710KW
 
 

Techincal Parameters:

 

1. Wake up and sleep function parameters:

 

P47.05 Light detection threshold If the output frequency is lower than this value and exceeds P47.06, it will be reported to Sleep and stop 0Hz
P47.06 Light detection time See P47.05 for explanation. 60s
P47.07 Light weak wake up time After the sleep fault is reported, if the time when Vdc is higher than the undervoltage point is greater than the set value, the fault state is exited and the operation continues. 600s

 

2. Dry runing protection function parameters:

 

P24.12 Dry run/Unload protection option

0: No offload detection is performed;

1: Enable dry run detection

1
P24.13 Dry run/Unload detection level

0.0 to 200.0%

The percentage of motor rated current.

0.0%
P24.14 Dry run Unload detection time 0.000s~60.000s 30.000s
P24.15 Unload detection offset frequency

0.00Hz~Fmax

Detection frequency=Fmax-P24.15

 

5.00Hz
P24.16 Reset time of dry run protection 0.0~6000.0 240.0s
P23.21 Dry run detection mode

0000:Coast stop

1000:Fast stop

3000:Continue to run

0000

 

3. Water full protection function parameters:

 

P47.18 Full water level detection channel

0:ineffective

1:AI1

2:AI2

3:AI3

4:AI4

Note: DI terminal function code 60-full water level detection is same with Analogue detection, and the detection time and recovery time are the same.

0
P47.19 Full water level detection value

0.0~100.0%

 

 

0.0%
P47.20 Full water level detection time

0.0~3000.0s

When DI-60 is valid or meets the analog detection channel greater than P47.19 and maintains P47.20 time, the system reports A.Full and stops.

 

10.0s
P47.21 Full water recovery time

0.0~3000.0s

When the condition described in P47.20 does not meet full water level detection requirement ,it will be returned to normal state after delay

10.0s

 

 
 