-
Tayfun from Turkeysolar pump inverter is really in very good quality and we also prepared some promotional products for exhibition. We are going to make new orders soon. Last year there was only one local agent and this year, there are more than 8. Some of them only sell Veikong!
-
Cristian from ChileIt’s very good! LCD options make it much easier to use. That’s the strong point, easy of use. And robust. Great PC software.
-
Brahim assad from SyriaVFD500 output frequency is stable when the others are fluctuating. Also output current is less than others, that’s why output frequency is higher too which can save more energy.
Place of Origin | China |
---|---|
Brand Name | VEIKONG |
Certification | CE |
Model Number | VFD530 |
Minimum Order Quantity | 1 |
Price | Negotiable |
Packaging Details | the power less than 45kw use Carton, starting from 45kw use Wooden case |
Delivery Time | 3 days, depend on the order quantity |
Payment Terms | L/C, T/T, Western Union |
Supply Ability | 15000pcs per Month |
Product Name | PMSM Converter | Power | 2.2kw 4kw 5.5kw |
---|---|---|---|
Phase | Single Phase/three Phase | Communciation | Modbus 485 Profinet Canopen |
Frequency | 0-3000hz | Control Mode | Vf/vector Control |
High Light | 5.5 Kw VFD PMSM Driver,Asynchronous Motor 5.5 Kw VFD,Asynchronous Motor 2.2 kw vfd |
High performance
1. More Accurate Motor Autotuning
2. Advanced open and close loop vector control
3. Perfect voltage and current control, reducing the fault protection times
4 Multiple braking modes and instant stopping
5. 0.75kW~7100kW(Three Phase 400V)
1, With inside EMC C3 filter and building-block design for IO extension card and different kinds of PG card2, Up to 200% starting torque at 0HZ. Out frequency up to 3000HZ.
3, Support optional LCD keypad and dual display keypad. support PC tools. support modbus485, canopen, profinet communciation.
4, Support Asynchornous & Synchronous motor.
5, Support 2 PID loop for HVAC
6,Sleeping function and energy saving function as well as in built PLC programming
7, Special brake logic mechanism for crane and hoist, Magnetic flux brake gain
8,Support two group motor parameters which can realize two motor switching control9, Built-in braking unit (≤22kW), Optional external braking unit (≥30kW)10, Accurate parameters auto tuning and better motor drive
Item | Specifiation | |
Input | Inuput Voltage |
1phase/3phase 220V:200V~240V 3 phase 380V-480V:380V~480V |
Allowed Voltage fluctuation range | -15%~10% | |
Input frequency | 50Hz / 60Hz,fluctuation less than 5% | |
Output | Output Voltage | 3phase:0~input voltage |
Overload capacity |
General purpose application:60S for 150% of the rated current Light load application:60S for 120% of the rated current |
|
Control | Control mode |
V/f control Sensorless flux vector control without PG card(SVC) Sensor speed flux vector control with PG card (VC) |
Operating mode | Speed control,Torque control(SVC and VC) | |
Speed range |
1:100 (V/f) 1:200( SVC) 1:1000 (VC) |
|
Speed control accuracy |
±0.5% (V/f) ±0.2% (SVC) ±0.02% (VC) |
|
Speed response |
5Hz(V/f) 20Hz(SVC) 50Hz(VC) |
|
frequency range |
0.00~2000.00Hz(V/f) 0.00~200.00Hz(SVC) 0.00~400.00Hz(VC) |
|
Input frequency resolution |
Digital setting: 0.01 Hz Analog setting: maximum frequency x 0.1% |
|
Startup torque |
150%/0.5Hz(V/f) 180%/0.25Hz(SVC) 200%/0Hz(VC) |
|
Torque control accuracy |
SVC:within 5Hz10%,above 5Hz5% VC:3.0% |
|
V/f curve |
V / f curve type: straight line, multipoint, power function, V / f separation; Torque boost support: Automatic torque boost (factory setting), manual torque boost |
|
Frequency giving ramp |
Support linear and S curve acceleration and deceleration; 4 groups of acceleration and deceleration time, setting range 0.00s ~ 60000s |
|
DC bus voltage control |
Overvoltage stall control: limit the power generation of the motor by adjusting the output frequency to avoid skipping the voltage fault;
Undervoltage stall control: control the power consumption of the motor by adjusting the output frequency to avoid yaw failure
VdcMax Control: Limit the amount of power generated by the motor by adjusting the output frequency to avoid over-voltage trip; VdcMin control: Control the power consumption of the motor by adjusting the output frequency, to avoid jump undervoltage fault |
|
Carrier frequency | 1kHz~12kHz(Varies depending on the type) | |
Startup method | Direct start (can be superimposed DC brake); speed tracking start | |
Stop method | Deceleration stop (can be superimposed DC braking); free to stop | |
Maincontrol function | Jog control, droop control, up to 16-speed operation, dangerous speed avoidance, swing frequency operation, acceleration and deceleration time switching, VF separation, over excitation braking, process PID control, sleep and wake-up function, built-in simple PLC logic, virtual Input and output terminals, built-in delay unit, built-in comparison unit and logic unit, parameter backup and recovery, perfect fault record,fault reset, two groups of motor parametersfreeswitching, software swap output wiring, terminals UP / DOWN | |
Function | Keypad | LED Digital keyboard and LCD keypad(option) |
Communication |
Standard: MODBUS communication CAN OPEN AND PROFINET( IN DEVELOPMENT) |
|
PG card | Incremental Encoder Interface Card (Differential Output and Open Collector), Rotary transformer Card | |
Input terminal |
Standard: 5 digital input terminals, one of which supports high-speed pulse input up to 50kHz; 2 analog input terminals, support 0 ~ 10V voltage input or 0 ~ 20mA current input; Option card: 4 digital input terminals 2 analog input terminals.support-10V-+10V voltage input |
|
Output terminal |
standard: 1 digital output terminal; 1 high-speed pulse output terminal (open collector type), support 0 ~ 50kHz square wave signal output; 1 relay output terminal(second relay is an option ) 2 analog output terminals, support 0 ~ 20mA current output or 0 ~ 10V voltage output; Option card: 4 digital output terminals |
|
Protection | Refer to Chapter 6 "Troubleshooting and Countermeasures" for the protection function | |
Product series instruction:
Model |
Power capacity (KVA) |
Input current (A) |
Output current(A) |
Adaptable Motor (KW) |
SIZE | Brake Unit | |
Heavy load | Light load | ||||||
Three phase: 380-480V,50/60Hz | |||||||
VFD530-R75GT4B | 1.5 | 3.4 | 2.5 | 4.2 | 0.75 | SIZE A | Internal |
VFD530-1R5GT4B | 3 | 5 | 4.2 | 5.6 | 1.5 | ||
VFD530-2R2GT4B | 4 | 5.8 | 5.6 | 9.4 | 2.2 | ||
VFD530-4R0G/5R5PT4B | 5.9 | 10.5 | 9.4 | 13.0 | 3.7 | ||
VFD530-5R5G/7R5PT4B | 8.9 | 14.6 | 13.0 | 17.0 | 5.5 | SIZE B | |
VFD530-7R5G/011PT4B | 11 | 20.5 | 17.0 | 23.0 | 7.5 | ||
VFD530-011G/015PT4B | 17 | 26.0 | 25.0 | 31.0 | 11 | SIZE C | Internal |
VFD530-015G/018PT4B | 21 | 35.0 | 32.0 | 37.0 | 15 | ||
VFD530-018G/022PT4B | 24 | 38.5 | 37.0 | 45.0 | 18.5 | SIZE D | |
VFD530-022G/030PT4B | 30 | 46.5 | 45.0 | 57.0 | 22 | ||
VFD530-030G/037PT4 | 40 | 62.0 | 60.0 | 75.0 | 30 | SIZE E | option |
VFD530-037G/045PT4 | 50 | 76.0 | 75.0 | 87.0 | 37 | ||
VFD530-045G/055PT4 | 60 | 92.0 | 90.0 | 110.0 | 45 | SIZE F | |
VFD530-055G/075PT4 | 75 | 113.0 | 110.0 | 135.0 | 55 | ||
VFD530-075G/090PT4 | 104 | 157.0 | 152.0 | 165.0 | 75 | SIZE G | |
VFD530-090G/110PT4 | 112 | 170.0 | 176.0 | 210.0 | 90 | External | |
VFD530-110G/132PT4 | 145 | 220.0 | 210.0 | 253.0 | 110 | SIZE H | |
VFD530-132G/160PT4 | 170 | 258.0 | 253.0 | 304.0 | 132 | SIZE I | |
VFD530-160G/185PT4 | 210 | 320.0 | 304.0 | 360.0 | 160 | ||
VFD530-185G/200PT4 | 245 | 372.0 | 360.0 | 380.0 | 185 | SIZE J | |
VFD530-200G/220PT4 | 250 | 380.0 | 380.0 | 426.0 | 200 | ||
VFD530-220G/250PT4 | 280 | 425.0 | 426.0 | 465.0 | 220 | SIZE K | |
VFD530-250G/280PT4 | 315 | 479.0 | 465.0 | 520.0 | 250 | ||
VFD530-280G/315PT4 | 350 | 532.0 | 520.0 | 585.0 | 280 | SIZE L | |
VFD530-315G/355PT4 | 385 | 585.0 | 585.0 | 650.0 | 315 | ||
VFD530-355G/400PT4 | 420 | 638.0 | 650.0 | 725.0 | 355 | SIZE M | |
VFD530-400G/450PT4 | 470 | 714.0 | 725.0 | 820.0 | 400 | ||
VFD530-450G/500PT4 | 530 | 800.0 | 820.0 | / | 450 | SIZE N | |
VFD530-500G/560PT4 | 580 | 880.0 | 900.0 | / | 500 | ||
VFD530-560G/630PT4 | 630 | 950.0 | 980.0 | / | 560 | SIZE O | |
VFD530-630GT4 | 710 | 1080 | 1120. | / | 630 | SIZE O | |
VFD530-710GT4 | 790 | 1200 | 1260 | / | 710 | SIZE O | |
Single phase :220V ,50/60HZ | |||||||
VFD530-R40GS2 | 1.3 | 6.0 | 3.2 | 5.6 | 0.4 | SIZE A | Inbuilt |
VFD530-R75GS2 | 2.4 | 11.0 | 5.6 | 8.0 | 0.75 | SIZE A | |
VFD530-1R5GS2 | 3.5 | 15.0 | 8.0 | 10.6 | 1.5 | SIZE A | |
VFD530-2R2GS2 | 5.5 | 25.0 | 10.6 | 14.0 | 2.2 | SIZE A | |
VFD530-4R0GS2 | 7.7 | 35.0 | 17.0 | 23.0 | 4.0 | SIZE B | |
VFD530-5R5GS2 | 8.9 | 53.0 | 25.0 | 31.0 | 5.5 | SIZE C | |
VFD530-7R5GS2 | 11 | 67.0 | 32.0 | 37.0 | 7.5 | SIZE C |
VEIKONG VFD application:
VEIKONG VFD replace famous brands
