Product Name | 250kw Bypass Soft Starter | Output Frequency | 50/60Hz |
---|---|---|---|
Display | LCD Display | Type | Bypass Type |
Application | Motor,Crusher,Home Appliance,all Kinds Of 3 Phase Pumps,water Pump | Protection | Input/Output Phase Protection,IP20,Overcurrent Protection,and Short Circuit,Three-phase Unbalance Protection |
High Light | VEIKONG 250 Kw Soft Starter,250 Kw Solid State Soft Starter,Crusher 250 Kw Soft Starter |
250kw 300kw 400kw 500kw bulit in Bypass Soft Starter for ac motor protection
Product feature
VKS-8000 is a highly intelligent, very reliable and easy to use soft starter. The newly designed functions of VKS-8000 are used for quick setting or more personalized control.
It's a perfect solution. Its performance includes:
Large LCD screen that can display feedback information in Chinese and English languages, other languages can be customized.
Remotely installable operation panel.
Intuitive programming.
Advanced start and stop control functions.
A series of motor protection functions.
Extensive performance monitoring and event logging.
Technical Specification
Item | Description | ||
Input Power Supply | Input Voltage | Three-phase 380V/480V/660 AC | |
Frequency | 50/60Hz | ||
Adaptive Motor | Squirrel-cage three-phase asynchronous motor | ||
Starting Times | It is recommended not to exceed 20 times per hour. | ||
Control Mode |
(1) Operation panel control. (2) Operation panel + external control. (3) External control. (4) External control + COM control. (5) Operation panel + external + COM control. (6) Operation panel + COM control. (7) COM control. (8) No start or stop operation. |
||
Start Mode |
(1) Current-limiting to start. (2) Voltage ramp to start. (3) Torque control + current-limiting to start. (4) Torque control + voltage ramp to start. (5) Current ramp to start. (6) Voltage current-limiting double closed-loop start. |
||
Stop Mode |
(1) Soft stop. (2) Free stop. |
||
Protective Function |
(1) Open loop protection for external instantaneous stop terminals. (2) Over-heat protection for soft starter. (3) Protection for too long starting time. (4) Input open phase protection. (5) Output open phase protection. (6) Unbalanced three-phase protection. (7) starting over current protection. (8) Running overload protection. (9) Under voltage protection for power voltage. (10) Overvoltage protection for power voltage. (11) Protection for fault parameter setting. (12) Load short circuit protection. (13) Auto restart or incorrect wiring protection. (14) Incorrect wiring protection of external control stop terminals. |
||
Ambient |
Place to be used | Indoor location with good ventilation free from corrosive gas and conductive dust. | |
Altitude |
Below 1000M. It have to rise the rate power when the altitude is more than 1000M. |
||
Temperature | -20 +45 C | ||
Humidity | 90%RH without dew condensation. | ||
Vibration | <0.5G | ||
Structure | Protection Class | IP20 | |
Cooling Pattern | Fans cooling. |
Run the simulation
In the absence of three-phase power or load motor, the soft start control loop can be tested, which is convenient for users to test.
Product Application
Protocol
The factory is Modbus protocol, and PROFIBUS communication protocol can be customized, which can facilitate communication with German Siemens PLC and touch screen.
PPT100 temperature sensor
Working with an external PPT100 temperature sensor, it can display the motor temperature in real time and better monitor the electricalMachine operation and protection of the motor.
Password control
After the user parameter debugging is completed, it can be locked with a password to prevent others from changing the parameters. The remote mobile phone APP function can be customized, remote control can be used, and the soft start load operation can be monitored.
Easier to install
If the space of the motor control center is limited, using the compact design of VKS-8000 can save space and eliminate unnecessary troubles. The built-in bypass contactor, built-in monitoring and indicator, and many control input and output functions can reduce the installation space and cost of external equipment, and can also simplify the installation.